Analisis Efektivitas Alat Penukar Kalor Pelat Datar UFX-42H Terhadap Kebocoran Pelat Dalam Proses Elusi Emas

Authors

  • Annisa Sekarayu Permanajati Universitas Pancasila
  • La Ode M. Firman Universitas Pancasila

DOI:

https://doi.org/10.35814/asiimetrik.v3i2.2163

Keywords:

plate heat exchanger, effectiveness, log mean temperature different

Abstract

Heat exchanger is an equipment designed to exchange heat between two fluids by applying heat transfer by convection and conduction without mixing the two fluids. heat exchangers are used in the gold mining industry in the gold elution process stage with the type of alat penukar kalor pelat datar(PHE) UFX-42H to reheat the eluate (water) using glycol as the heating fluid. The PHE has a leak on the back base plate. This report aims to analyze the comparison of the effectiveness and LMTD of PHE between specification data and operational data at the time of leakage. The calculation off effectiveness requires the suhue, mass flow rate, and specific heat of the fluid. The results obtained were the effectiveness of the specification data is 0.83 and the mean of operational data is 0.71. The results of LMTD specification data is 23.91 and the mean of operational data is 28.1.

Downloads

Download data is not yet available.

Author Biographies

  • Annisa Sekarayu Permanajati, Universitas Pancasila

     

     

  • La Ode M. Firman, Universitas Pancasila

     

     

References

Azari, N., dkk., 2019. Experimental Investigation of Heat Transfer in Compact Heat Exchanger using Water-Ethylene Glycol, 8(04), International Journal of Engineering Research & Technology (IJERT), hal. 666–669.

Cengel, Y. A. dan Ghajar, A. J., 2015. Heat and Mass Transfer. Fifth Edit.'New York: Mc Graw Hill Education.

Egeten, H. S. F. dkk., 2014. Efektivitas Penukar Kalor Tipe Plate P41 73Tk, Skripsi, Manado : Universitas Sam Ratulangi.

Ezgi, C., 2017. Basic Design Methods of Heat Exchanger, IntechOpen. doi: http://dx.doi.org/10.5772/67888.

Keith, F. dan Prijono, A., 2018. Prinsip-prinsip Perpindahan Panas. Edisi Ketiga. Jakarta: Penerbit Erlangga.

Lathuef, S. A. dkk., 2016. Design and Thermal Analysis of A Plate Heat Exchanger, International Journal of Academic Studies. 2(5), hal. 303-308.

Mota, F. A. S. dkk., 2015. Modeling and Design of Plate Heat Exchanger, InTech. doi: http://dx.doi.org/10.5772/60885.

Picon-Nunez, M., dkk., 2018. Use of Heat Transfer Enchancement Techniques in the Design of Heat Exchangers, IntechOpen. doi: http://dx.doi.org/10.5772/intechopen.78953.

Salman, T., dkk., 2016. Performance Analysis of Corrugated Plate Heat Exchanger With Water As Working Fluid, International Journal of Research in Engineering and Technology, 05(04), hal. 56–62. doi: 10.15623/ijret.2016.0504012.

Syah, H., 2013. Kajian Kinerja Penukar Panas Tipe Shell and Tube Satu Haluan dengan Pengontrolan Suhu Outlet, Jurnal Rekayasa Kimia dan Lingkungan, 9, hal. 158–165. doi: http://dx.doi.org/10.23955/rkl.v9i4.1228.